( Brand: Omron ), ( Manufacturer Part Number: E5CC-RX2ASM-880 ), ( Part Type: Controller ), ( Country/region Of Manufacture: Taiwan )
The E5CC-RX2ASM-880 110-240V Controller Temperature from Omron is a sophisticated and reliable temperature controller designed for various industrial applications. This controller is equipped with an adjustable setpoint temperature range, allowing users to accurately control the temperature within their specific requirements.
The E5CC-RX2ASM-880 features a user-friendly interface, making it easy for operators to set and monitor temperature settings. It includes a high-resolution LCD display that clearly shows temperature readings, setpoint values, and other crucial information. The controller also includes a bright backlight, ensuring visibility in various lighting conditions.
This temperature controller is built with robustness and durability in mind. It has a sturdy metal enclosure that protects it from harsh industrial environments, including dust, moisture, and vibrations. The controller is also compatible with a wide range of temperature sensors, allowing for versatility in its application.
The E5CC-RX2ASM-880 is designed to operate on a 110-240V power supply, making it suitable for use in various regions worldwide. It also includes safety features such as over-temperature protection and short-circuit protection, ensuring the safe operation of the controlled system.
In conclusion, the E5CC-RX2ASM-880 110-240V Controller Temperature from Omron is an excellent choice for industrial applications requiring precise temperature control. Its user-friendly interface, robust design, and wide compatibility make it a reliable and flexible solution for various temperature control needs.
Pros of buying a E5CC-RX2ASM-880 110-240V controller temperature from Omron:1. Wide voltage range: The controller supports a voltage range of 110-240V, making it suitable for use in various regions worldwide.
2. Temperature control: The controller has a built-in temperature sensor, enabling users to monitor and control the temperature of their equipment.
3. Reliability: Omron is a reputable brand known for its high-quality and reliable products.
4. Easy to use: The controller has an intuitive interface, making it easy for users to operate and program.
Cons of buying a E5CC-RX2ASM-880 110-240V controller temperature from Omron:1. Cost: The controller may be more expensive than some other alternatives on the market.
2. Limited connectivity: The controller may not offer advanced connectivity options, such as Wi-Fi or Bluetooth, which some users may require.
3. Limited programming capabilities: While the controller has an easy-to-use interface, it may not offer as many programming options as more advanced controllers.
Conclusion:The E5CC-RX2ASM-880 110-240V controller temperature from Omron is a reliable and easy-to-use option for temperature control in various applications. Its wide voltage range and built-in temperature sensor make it a versatile choice, while its reputation for quality and reliability adds peace of mind for users. However, its relatively high cost and limited connectivity and programming capabilities may be a drawback for some users. Ultimately, the decision to purchase this controller depends on the specific needs and budget of the user.
Recommendation:If the user needs a reliable and easy-to-use temperature controller with a wide voltage range and built-in temperature sensor, the E5CC-RX2ASM-880 110-240V controller temperature from Omron is a solid choice. However, users who require advanced connectivity or programming capabilities may want to consider alternative options that may offer more features at a higher cost.
3 ambient temperature c to 23 c to 55 c, voltage range to 10 of rated voltage 4 k Thermopylae at c max. Heater burnout alarm setting range Toni units of MTV absolute value upper limit alarm 9 standard control standard control this alarm type turns on the alarm when the manipulated variable MTV is higher than the alarm value x. H174 for information on the loop burnout alarm Lab.
Please for exact shipping cost. 1 or higher is required. Other Thermopylae input of PVC or 4 c, whichever is greater 1 digit max.
road postwar, NJ of PVC or 3 c, whichever is greater 1 digit max the alarm is on when the PVC is outside this deviation range.
Load current 21 ma, with short circuit protection circuit linear current output 4 to 20 ma dc to 20 ma dc, load max. Current flow approx. Control method on off control or 2 paid control with auto tuning control output relay output e5cc 800 psst no, 250 vac, 3 a restive load, electrical life 100,000 operations, minimum applicable load 5 v, 10 ma e5cc u 800 PDT, 250 vac, 3 a restive load, electrical life 100,000 operations, minimum applicable load 5 v, 10 ma voltage output for driving SSE output voltage 12 CDC NP, max g, mounting bracket approx.
9 fs in units of Lab alarm 1 type only PVC change rate alarm Sp absolute value upper limit alarm this alarm type turns on the alarm when the set point Sp is higher than the alarm value x. 8 industrial electromagnetic environment en IRC table 2 communications specifications transmission line connection method rs 485 multi drop communications rs 485 two wire, half duplex synchronization method start stop synchronization protocol compo way f, or mod bus baud rate, 192 384 or bps transmission code ASCII data bit length 7 or 8 bits stop bit length 1 or 2 bits error detection vertical parity none, even, odd block check character CBC with compo way f or CRX 16 mod bus flow control none interface rs 485 retry function none communications buffer 217 bytes communications response wait time toms default 20 ms the baud rate, data bit length , stop bit length , and vertical parity can be individually set using the communications setting level case 3 always off 5. Auxiliary outputs are allocated for alarms. Heating cooling control cooling MTV heating cooling control cooling MTV always on 1 with set values 1, 4 and 5, the upper and lower limit values can be set independently for each alarm type, and are expressed as l and.
2 fs 1 digit max. 7 the e5cc u 800 plug in model is certified for ul listing only when used together with the Omron p2cf 11 or p2cf 11 e socket. The p3ga 11 is not certified for ul listing. 8 c, whichever is greater 1 digit analog input orders above 150 lbs.
9in units of. To can be shipped by us.
1 or higher is required for the Fox series or the JV series. 1 c or f analog input refer to the e5 c digital controllers user's manual cat. The indication accuracy of the b Thermopylae at a temperature of 400 c max.
H174 for information on the operation of the standby sequence absolute value upper limit the alarm will turn on if the process value is larger than the alarm value x regardless of the set point. 2 of PVC or set value 5, upper and lower limit with standby sequence always off when the upper limit and lower limit hysteresis overlaps. 15 control period 0.
Orders being shipped to PO. 1 c or f analog input to e5cc u 800 Thermopylae of PVC or 2 c, whichever is greater 1 digit max. To the alarm is on when the PVC is inside this deviation range.
Heater burnout detection current value. 9in units of 0.
Characteristics indication accuracy at the ambient temperature of 23 c e5cc 800 Thermopylae 9 absolute value lower limit the alarm will turn on if the process value is smaller than the alarm value x regardless of the set point.
1 fs integral time I for cooling to 9999in units of 1,. Omron e5cc sexism 880 temperature controller 110 240v ratings power supply voltage a in model number 100 to 240 vac, 50 60 hazing model number 24 vac, 50 60 Hz 24 CDC operating voltage range 85 to 110 of rated supply voltage power consumption model's with option selection of PO. 9 when heating cooling control is performed, the MTV absolute upper limit alarm functions only for the heating operation and the MTV absolute lower limit alarm functions only for the cooling operation.
Is not specified. Set value alarm type alarm output operation of function when alarm value x is positive when alarm value x is negative alarm function off output off no alarm 1 upper and lower limit set the upward deviation in the set point for the alarm upper limit and the lower deviation in the set point for the alarm lower limit l.
The indication accuracy of the r at a temperature of 200 c max. 1 alarm setting range to decimal point position depends on input type affect of signal source resistance Thermopylae w max. voltage input 1 m min.
Off leakage current Sp absolute value lower limit alarm this alarm type turns on the alarm when the set point Sp is lower than the alarm value x. Other functions manual output, heating cooling control, loop burnout alarm, Sp ramp, other alarm functions, heater burnout HBO alarm including SSE failure HS alarm, 40 at, 100 at, MTV limiter, input digital filter, self tuning, PVC input shift, run stop, protection functions, temperature status display, moving average of input value ambient operating temperature 10 to 55 c with no condensation or icing, for 3 year warranty 10 to 50 c with no condensation or icing ambient operating humidity 25 to 85 storage temperature 25 to 65 c with no condensation or icing altitude 2,000 m max. 3 the value is 30 ms for a control period of 0.
Is 3 c 1 digit max. The indication accuracy of pl ii Thermopylae's ism, SUV 7. 4 upper and lower limit range set the upward deviation in the set point for the alarm upper limit and the lower deviation in the set point for the alarm lower limit l.
2 influence of temperature 3 Thermopylae input r,, b, w, pl ii of PVC or c, whichever is greater 1 digit max.
Influence of voltage 3 influence of ems. The alarm is on when the PVC is higher than the Sp by the deviation or more.
The indication accuracy of w Thermopylae's is.
Use a 1/1 connection when connecting the es2 HBO TB. Orders under 150 lbs. Off 100 k min.
5 the unit is determined by the setting of the integral derivative time unit parameter. At 24 CDC sensor input temperature input Thermopylae k, j, t, e, l, u, n, r,, b, w, or pl ii platinum resistance thermometer pt100 or jpt100 infrared temperature sensor es1b 10 to 70 c, 60 to 120 c, 115 to 165 c, or 140 to 260 c analog input current input 4 to 20 ma or to 20 ma voltage input 1 to 5 v, to 5 v, or to 10 v input impedance current input max.fs in units of. A temperature controller with version fs in units of 0.
SSE failure detection current value.
2 fs 1 digit max. At 24 vac or Number of connected digital temperature controllers 32 max. 01 fs proportional band temperature input 0.
15 proportional band for cooling temperature input platinum resistance thermometer check.
9in units of however, the precision between and 4 ma for a to 20 ma output is 1 fs max.
1 VA max lower limit set the downward deviation in the set point by setting the alarm value x. H174 for information on the PVC change rate alarm.
Analog input type current voltage input specification 4 to 20 ma to 20 ma 1 to 5 v to 5 v to 10 v setting range usable in the following ranges by scaling to 9999, w max. Resolution approx. 15 derivative tomato 9999in units of 1.
Platinum resistance thermometer. 2 of PVC or to VA max. 9 c or f in units of 0.
Refer to model number legend on lineup. 1or refer to the e5 c digital controllers user's manual cat. Non contact input on residual voltage including master copying 2 when digital temperature controllers are connected, the parameters can be copied from the digital temperature controller that is set as the master to the digital temperature controllers that are set as slaves.
1 to number of connected temperature controllers 32 max. 4 the value is 35 ms for a control period of toe5cc u 800 controller approx. 1 to ma max.
Slope and offsets can be set for the set point. The default is 2 upper limit. 999 set value alarm outputs each alarm can be independently set to one of the following 19 alarm types. Ct input 5 fs 1 digit max.
2g, mounting bracket approx. Insulation resistance 20 m min. 2/1 fs integral time I to 9999in units of 1, 0.
1 to no communications programming is required. 1 a minimum detection on time 100 ms 3 SSE failure alarm setting range ma per contact setting method digital setting using front panel keys indication method 11 segment digital display and individual indicators character height PVC max lower limit with standby sequence a standby sequence is added to the lower limit alarm 2 default upper limit set the upward deviation in the set point by setting the alarm value x.
9 a in units of 0.
Buyers can call or info adrenaline. 01 to upper and lower limit with standby sequence a standby sequence is added to the upper and lower limit alarm 9 a in units of 0.
Net for further information. The alarm is on when the PVC is lower than the Sp by the deviation or more. 1 to in units of.
15 derivative time for cooling to 9999in units of 1,. Heating cooling control heating MTV heating cooling control heating MTV always on 17 MTV absolute value lower limit alarm 9 standard control standard control this alarm type turns on the alarm when the manipulated variable MTV is lower than the alarm value x. Analog input 1 fs 1 digit max.
At 500 CDC dielectric strength 3,000 vac, 50 60 Hz for 1 min between terminals of different charge vibration malfunction 10 to 55 Hz, 20 m s2 for 10 min each in x, y, and z directions resistance 10 to 55 Hz, 20 m s2 for 2 hrs each in x, y, and z directions shock malfunction 100 m s2, 3 times each in x, y, and z directions resistance 300 m s2, 3 times each in x, y, and z directions weight e5cc 800 controller approx. 7 refer to the e5 c digital controllers user's manual cat.
Ct input fs 1 digit max. The e5 c automatically performs communications with PCs. 5 g, e54 ct3 approx.
At 24 CDC all other model's see note. And u and l Thermopylae's at any temperatures is 2 c 1 digit max. 2 both the program less communications and the component communications support the copying. At 100 to 240 vac, and set value 1, upper and lower limit alarm 3 set value 4, upper and lower limit range 4 set value 5, upper and lower limit with standby sequence for upper and lower limit alarm described above case 1 and 2 always off when the upper limit and lower limit hysteresis overlaps.
Communications functions program less communications 1 you can use the memory in the plc to read and write e5 c parameters, start and stop operation, etc. 1 c or f analog input of PVC or 1 c, whichever is greater 1 digit max. 8 c, whichever is greater 1 digit analog input, 1 toes in units of 1 manual reset value to 99. 9 c or f in units of 0.
At 24 vac or ,000 auxiliary output number of outputs 2 output specifications psst no relay outputs, 250 vac, model's with 2 outputs 3 a restive load, electrical life 100,000 operations, minimum applicable load 10 ma at 5 v event input number of inputs 2 or 4 depends on model external contact input specifications contact input on 1 k max. 4 platinum resistance thermometer of PVC or 2 c, whichever is greater 1 digit max. At en input sampling period 50 ms hysteresis temperature input 0.
At 100 to 240 vac, and c or f in units of upper limit with standby sequence a standby sequence is added to the upper limit alarm c max. Current transformer order separately ratings dielectric strength 1,000 vac for 1 min vibration resistance 50 Hz, 98 m s2 weight e54 ct1 approx.